All evidence · Deutsche Fassung

Test report, Innovation and Industry Park Katowice 2018: Influence of PSC products (PScoat) on the thermal properties of a partition wall – full text

Title: Test report „Influence of PSC products on the thermal properties of the partition wall“
Testing body: Innovation and Industry Park (Park Innowacji i Przemysłu Sp. z o.o.), Analysis Team of the Research and Development Centre, ul. Francuska 13/7, 40-027 Katowice; production facility/laboratory stand: ul. Górniczego Stanu 130, 40-468 Katowice
Client: River Power s. r. o.
Order No.: 01/ 05/ 2018
Test period: 15.05.2018 – 30.07.2018
Project manager: Michał Marciniak
Issued on: 30 July 2018
Number of pages: 15 pages
Translation note: Certified translation from Polish by Łukasz Brzana, sworn translator and interpreter for the German language, register number TP/86/14, deed register no. 321/2022, Lublin, 14.03.2022.

Faithful English text version of the certified German translation of the Polish original. The original PDF is authoritative: pscoat-pruefbericht-katowice-2018-de.pdf

Table of contents (page 2 of the original)

  • 1. Description of the test stand — 3
  • 2. Description of the test devices — 5
  • 3. Description of the test method — 8
  • 4. Test — 10
  • A. Power consumption test — 10
  • Test purpose — 10
  • Conditions and description of the test — 10
  • Test results — 10
  • B. Thermal tests — 11
  • Test purpose — 11
  • Conditions and description of the test — 11
  • Test results — 12
  • C. Conclusions from the tests — 15

[page 2]

1. Description of the test stand

[page 3]

The test container consists of two sized analytical chambers (Fig. 1). The chambers are separated by a wall built of OSB boards filled with mineral wool. Plasterboards were screwed to both sides of the OSB boards (Fig. 4). 4 temperature sensors were installed in each of the chambers, as well as the cameras: industrial and thermal imaging camera. Possible functions are:

  • Temperature control in both chambers,
  • Recording of the electrical energy consumption required for the heating/cooling process,
  • Recording of the temperature prevailing in both chambers,
  • Image recording from both chambers.

[Diagram: Figure 1 – Sketch of the test stand. Two chambers „Cold zone (-15 °C)“ and „Warm zone (+20 °C)“, separated by „Partition wall“; in each chamber four temperature sensors and one camera station.]

K – Camera station (industrial and thermal imaging camera)

L1, L2, R1, R2 – Temperature sensors

2. Description of the test devices

[page 4]

LABORATORY STAND

[Photo: Figure 2 – View of the laboratory stand. Monitor workstation with several screens, table overviews of the temperature measurement, energy meter „LICZNIK ENERGII GRZANIA“ (heating energy meter) and a trend chart with repeated cycles.]

[Photo: Figure 3 – Photos of the partition walls of the laboratory stand. Four interior views of the test chambers, labelled „strefa ciepła“ (warm zone) and „strefa zimna“ (cold zone) in the original photos.]

[page 5]

PARTITION WALL

[Diagram: Figure 4 – Sketch of the cross-section of the partition wall between the warm and cold zone, with the layers plasterboard, OSB boards 12 mm, mineral wool 10 cm, OSB boards 12 mm, plasterboard.]

1 – Plasterboard with a thickness of 12 mm

2 – OSB board with a thickness of 12 mm

3 – Mineral wool with a thickness of 10 cm

Thermal imaging camera Optris(R) PI 640

Technical dataValue
Optical resolution640 x 480 pixels
DetectorFPA, uncooled (17 µm x 17 µm)
Temperature range:-20…+100 °C;
Spectral range:7.5 -13 µm
Optical resolution382 x 288 px
Thermal sensitivity (NETD)75 mK
Lenses (FOV)33° x 25°/f = 19 mm; 60° x 45°/f = 10 mm; 90° x 66°/f = 7 mm
Maximum refresh rate32 Hz
Accuracy±2 °C or ±2 % of reading
Interface typeUSB 2/0
Signal interface (PIF)Input 0-IO V, digital input, output 0-10V
Storage temperature-40 °C … 70 °C
Operating conditions of the deviceTemperature: 0 °C … 50 °C; relative humidity: 20~80 without condensation
Power supplyCamera supply via USB
Resistance to vibrations, shocks25G, IEC 68-2-29 / 2G, IEC 68-2-6
Tripod mounting thread1/4/20/UNC
Protection classIP 67 (NEMA4)
Dimensions46 mm x 56 mm x 90 mm
Weight320 g (incl. lens)

Table 1 – Parameters of the Optris(R) PI 640 thermal imaging camera [pages 5–6]

RST4R3 universal control unit with connected thermocouples

[page 6]

The RST4R3 control unit is designed for remote temperature measurement. Thanks to the built-in external temperature sensors, the RST4R3 control unit allows online observation and archiving of measurements. The RST4R3 control unit has a number of independent OUT output connections with a load of 2 A and voltage up to 120 V. The state of each connection can be controlled manually or automatically, according to conditions specified by the user as follows.

[page 7]

  • Reaching the upper or lower alarm temperature of any connected thermometer;
  • Availability and lack of availability or change of availability of any computer on the network, based on the ICMP protocol (ping);
  • periodically or at a defined date and time;
  • On or off state of any of the IN-OUT input connections.

Four independent connections for connecting thermometers or operating switches were made on the front panel of the RST4R3 control unit. For configuring the INOUT connections as input connections, the RST4R3 control unit uses the actions of switching the port on and off, which allows the generation of user-defined events. The measured temperature values are presented in the form of daily, weekly or monthly charts.

Basic parameters:

  • Operation of 6 independent parameters, using the OUT connections;
  • Operation of up to 8 temperature sensors, using the INOUT connections;
  • Operation of up to 4 two-state input connections, using the INOUT connections;
  • Operation of events depending on the measured temperature;
  • Achievement of a corresponding temperature difference on the two specified thermometers;
  • Operation of events depending on date and time or periodically;
  • Logs of the operations performed;
  • Rescue mode in the network configuration and firewall to protect against loss of remote control;
  • wide range of input voltage 7-25 V;
  • Power supply via POE (Power Over Ethernet).

[page 8]

Additional parameters in the software version:

  • Access to measured temperatures using the XML protocol;
  • Operation of the humidity sensor;
  • central management of many control units via the web client interface;

3. Description of the test method

The test was based on creating climatic conditions that most closely approximate those prevailing in winter: -1 °C outdoors and +20 °C indoors. The purpose of the test is to determine how the application of products of the PSC company affects the heat transfer through the test partition wall. Tests were carried out on the test partition wall in the following variants:

  1. Plasterboard (GK) on both sides – without application of the PSC System
  2. Plasterboard (GK) on both sides – coated on the cold side with the PSC System
  3. Plasterboard (GK) on both sides + on the cold side: styrofoam with a thickness of 10 cm without application of the PSC System
  4. Plasterboard (GK) on both sides – coated on the cold side with the PSC System and paint (an element of the PSC System)

[Diagram: Sketch „PARTITION WALL“ – Version: GK]

[Diagram: Sketch „PARTITION WALL“ – Version: PSC]

[page 9]

[Diagram: Sketch „PARTITION WALL“ – Version: STIO]

[Diagram: Sketch „PARTITION WALL“ – Version: PSC + PSC Farbe]

Figure 5 – Sketch of the partition wall cross-sections between the warm and cold zone – variants

Samples for the test:

PSC insulation system

  • Primer
  • Thermal layer
  • PSC facade paint

All elements of the systems are water-dilutable systems. The total thickness of the system layer is 0.35 mm, and the thickness of the PSC paint layer itself is 0.1 mm.

FieldInformation
Samples testedPSC System
Sample collection pointThe client personally submitted the samples at the testing facility
Date and time of sample acceptance for the tests28-05-2018 10:00
Project managerMichał Marciniak

4. Tests

[page 10]

A. Power consumption tests

Test purpose

The purpose of the test is to determine the influence of the application of products of the PSC series on the consumption of electrical energy required to maintain the temperature level in the warm zone – simulation of the resulting savings thanks to the application of products of the PSC series.

Conditions and description of the test

The test was based on maintaining an average temperature for 24 h in the warm (20 °C) and cold (-15 °C) zone. Stable thermal conditions were established in both zones of the simulator, which were subsequently maintained for a total duration of 24 hours. The cost of maintaining the temperature in the cold zone was not measured; stability of the „external conditions“ was assumed, whereas the consumption of electrical energy required to maintain the temperature in the warm zone was the subject of this test. The measurements of current and temperature were carried out using the devices described in point 2.

Test result

The test results are presented below in table form as well as a chart. The savings between the individual versions of the partition walls were recorded in absolute terms – the savings relating to the base partition wall.

Partition wall versionConsumption over 24h kWSAVING
GK6.58–
PSC4.3833.43 %
ST10.4.4831.91 %
PSC + PSC-Farbe4.0837.99 %

Table 2. Test results of the electrical energy consumption [page 10]

[page 11]

[Diagram: Fig. 6 Diagram of the power consumption – saving in absolute terms. Bars for the versions GK, Styropian 10 cm, PScoating, PScoating + Farba PSC, with the „PScoat“ logo; the only clearly legible figure is „8.93 %“ at the „PScoat + PScoat“ bar; further percentage values printed inside the chart itself are not unambiguously legible in the scan [unleserlich/illegible] – the corresponding figures are in Table 2.]

B. Thermal tests

Test purpose

The purpose of the test is to determine the influence of the application of products of the PSC company on the temperature level in the warm zone. The simulation allows determining the possibility of achieving a higher temperature while maintaining constant heating expenses – achieved thanks to products of the PSC series.

Conditions and description of the test

The course of the test started with bringing the warm (20 °C) and cold (-15 °C) zone to the specified temperature, and then the course of the test proceeded with switching off the heating in the warm zone while maintaining constant conditions in the cold zone. The test was based on observing the cooling process of the warm zone in repeated 8-hour cycles. The cost of maintaining the temperature in the cold zone was not measured; stability of the „external conditions“ was assumed, whereas the observation of the course of the temperature changes in the unheated

[page 12]

warm zone was the subject of the present test. The temperature measurements were carried out using the devices described in point 2.

Test result

The test results are presented below in table form as well as a chart. The savings between the individual versions of the partition walls were recorded in absolute terms – the savings relating to the base partition wall.

GKST 10PSC
Temperature – test start22.4322.4321.3
Temperature – test end8.310.711
Temperature drop14.1311.7310.3
Temperature difference relative to GKn/a2.43.83
Advantage relative to the 1st partition wall variant16.99 %27.11 %

Table 4 – Comparative results of the cooling of the zones in different partition wall variants [page 12]

[Diagram: Figure 7 – Diagram of the cooling of the zones in the partition wall variant without and with application of PSC products and of styrofoam with a thickness of 10 cm – entire cooling process. Curves for GK, Styropian 10 cm and PScoat; axis labels are not unambiguously legible in the scan [unleserlich/illegible].]

[page 13]

[Diagram: Figure 8 – Diagram of the cooling of the zones in the partition wall variant without and with application of PSC products of a thermal insulation as well as with application of PSC products and of styrofoam with a thickness of 10 cm – temperature stabilisation. Curves for GK, Styropian 10 cm and PScoat; axis labels are not unambiguously legible in the scan [unleserlich/illegible].]

PSCPSC + PSC-Farbe
Temperature – test start21.322.09
Temperature – test end1112.24
Temperature drop10.39.5
Temperature differencen/a0.8
Advantage relative to the 1st partition wall variant7.97 %

Table 5 – Comparative results of the cooling of the zones in different partition wall variants [page 13]

[page 14]

[Diagram: Figure 9 – Diagram of the cooling of the zones in the partition wall variant using PSC products on the cold side – in the version without application and with application of the PSC paint on the warm side – entire cooling process. Curves „PScoat“ and „PScoat + PScoat“; axis labels are not unambiguously legible in the scan [unleserlich/illegible].]

[Diagram: Figure 10 – Diagram of the cooling of the zones in the partition wall variant using PSC products on the cold side – in the version without application and with application of the PSC paint on the warm side – temperature stabilisation. Curves „PScoat“ and „PScoat + PScoat“; axis labels are not unambiguously legible in the scan [unleserlich/illegible].]

C. Conclusions from the test

[page 15]

Power consumption test

  1. The application of products from the PSC series allows savings in heating expenses at a level of about 30 %.
  2. The application of products from the PSC series allows savings in heating expenses at a somewhat better level than 10 cm styrofoam with a thermal transmittance coefficient Lambda 0.044 [W/mK].
  3. The application of the PSC paint, which is an element of the PSC System, on the warm side of the partition wall (with application of a complete PSC System on the cold side) made it possible to achieve additional savings at a level of 9 % of energy consumption.

Thermal tests

  1. The application of products from the PSC series allows the achievement of advantages at a level of 25 % relative to the non-insulated partition wall.
  2. The application of products from the PCS series allows the achievement of a temperature increase at a better level than 10 cm styrofoam with a thermal transmittance coefficient Lambda 0.044 [W/mK].
  3. The application of the PSC paint, which is an element of the PSC System, on the warm side of the partition wall, made it possible to achieve a temperature increase of 8 %.
FieldInformation
Issued on30 July 2018
Authorised by[Long stamp with the content:] Analysis Team of the Research and Development Centre of the Innovation and Industry Park [illegible signature]; [Long stamp with the content:] Park Innowacji i Przemysłu [Innovation and Industry Park] Sp. z o.o., ul. Francuska 13/7, 40-027 Katowice, NIP [Tax ID]: 9542748952; [Long stamp with the content:] Michał Marciniak [illegible signature], Member of the Management Board

Footer of the original document (repeated verbatim on pages 3–15): „Management office: ul. Francuska 13/7, 40-027 Katowice. Production facility: ul. Górniczego Stanu 130, 40-468 Katowice. park-innowacji.pl, kontakt@park-innowacji.pl. NIP [Tax ID]: 954-274-89-52. REGON [Company ID]: 243569358. [illegible signature]“

I, Łukasz Brzana, a sworn translator and interpreter of the German language, entered in the register of sworn translators/interpreters kept by the Minister of Justice under number TP/86/14, hereby certify the conformity of the translation with the original document in the Polish language submitted to me. The document comprises fifteen pages. The translation was also prepared on fifteen pages.

Deed register no.: 321/2022.

Lublin, 14.03.2022.