PScoat Evidence: Test Reports, Measurements, Certificates
PScoat is a CE-marked coating system under EN 15824, tested by the accredited laboratory EFEKT (Zabrze) and TÜV NORD Polska (mark ID 141649). Independent measurements document its thermal effect: a test-rig trial reduced energy demand by 33%, and a case study showed a calculated U-value improvement from 2.63 to 0.10 W/(m²K). The often-cited industry-association position paper against „energy-saving paints“ examined a different product (BAUTER Nano-Dämmung) and does not mention PScoat anywhere.
How it works
PScoat is a thin-film acrylic-resin coating system filled with vacuum-sealed microspheres that reflects a large share of incoming heat radiation instead of absorbing it like a conventional facade paint. This changes the thermal balance of the wall: less heat gain from outside in summer, less heat loss to the outside in winter — measurable in surface temperature, energy consumption and the U-value of the whole building component, not in a single material property of a 0.3–1 mm thin layer. That is why we deliberately separate material testing, component testing and building measurement below.
Evidence table
| Metric | Value | Tested by | Document |
|---|---|---|---|
| Energy savings in test rig | −33.4% (PSC) / −38.0% (PSC + facade paint) vs. uncoated reference; slightly better than 10 cm polystyrene (−31.9%) | Park Innowacji i Przemysłu, Katowice, 2018 (commissioned by River Power s.r.o.) | Test report PDF |
| U-value on a real wall | 0.14 W/(m²K) at approx. 0.5 mm coating | In-situ measurement, Testo 635-2, approx. 12 h | U-value report PSC-U-2026-001 (with photos) |
| Water absorption | 0.07 kg/(m²·h^0.5), class W3 | EFEKT, Zabrze (accredited, PCA AB 1703) | Declaration of Performance PSC250T-2026-01 (on request) |
| Tensile adhesion strength | 1.4 N/mm² (concrete), 0.8 N/mm² after 20 freeze–thaw cycles | EFEKT, Zabrze | Declaration of Performance PSC250T-2026-01 (on request) |
| CE marking | under EN 15824, AVCP system 3 | — | Declaration of Performance PSC250T-2026-01 (on request) |
| Product certification | TÜV NORD Polska „Verified Product“, mark ID 141649 | TÜV NORD Polska | Verifiable online: cert.tuv-nord.pl |
| Weathering resistance | 1000 h artificial weathering, no visible change | IMparat, Hamburg, 2017 | Test protocol on request |
For the tested system, at 0.35 mm layer thickness, the test rig showed a system thermal resistance of R = 2.493 m²K/W (Katodesk-tech study, Katowice). This is explicitly not a material property — it describes the measured overall performance of the system at exactly this thickness and does not increase linearly with thickness; for that reason we do not state a lambda value for it. The coating’s material value is 0.0324 W/(m·K) per PN-EN 1745.
Case studies
Residential building, built 1890
Wall surface temperature before coating 12 °C, after 19 °C (under comparable winter conditions, 2–5 °C outside, 20 °C room temperature). Annual heating demand dropped from roughly 40,000 kWh to below 15,000 kWh — more than 60% less. Thermal images: see pscoat.de/messungen.
Multi-family building, built approx. 1960
Concrete-frame structure, 1 mm PScoat system (primer + build + finish). After application (April 2024), the calculated U-value fell from 2.632 to 0.096 W/(m²K), confirmed by thermal imaging; interior surface temperature rose from 13.0 °C to 19.7 °C, no condensation observed. Case study PDF.
These are documented individual cases, not a statistical series of measurements. How much a given building benefits depends on wall construction, condition and boundary conditions — which is why we offer an optional before/after U-value measurement with every package.
Certificates & CE
- CE marking under EN 15824, Declaration of Performance PSC250T-2026-01, AVCP system 3, tested by the accredited laboratory EFEKT, Zabrze (PCA accreditation AB 1703, ILAC-MRA — internationally recognized).
- TÜV NORD Polska „Verified Product“, mark ID 141649, verifiable online at cert.tuv-nord.pl.
- Technical data sheets and safety data sheets: on request.
- DIBt opinion on building-code classification (German Institute for Building Technology, letter dated 02.03.2026, President Dipl.-Ing. Gerhard Breitschaft, to the Federal Ministry for Housing, Urban Development and Building, BMWSB, addressed to Dennis Janik): confirms that products carrying the CE marking under EU Regulation 305/2011 do not require a general building-authority approval (abZ, cf. § 16c sentence 2 MBO) and may be used under the German states‘ building codes if the declared performance matches the intended use (§ 16c sentence 1 MBO); no separate ‚recognition‘ is required. Classification: not an abZ, but confirmation that no abZ is required. Original quote (German): „dass wir für Produkte, die die CE-Kennzeichnung nach der VO (EU) 305/2011 tragen, keine allgemeinen bauaufsichtlichen Zulassungen (vgl. § 16c Satz 2 MBO) erteilen und dass diese Bauprodukte nach den Bauordnungen der Länder verwendet werden können, wenn die erklärten Leistungen den Anforderungen für diese Verwendung entsprechen (vgl. § 16c Satz 1 MBO). Ergänzend haben wir auch mitgeteilt, dass es einer ‚Anerkennung‘ nicht bedarf.“ Our own classification: PSC-BA-2026-01 (PDF).
The paint-industry position paper does not concern PScoat
In January 2026, several German trade associations — led by the Verband für Dämmsysteme, Putz und Mörtel e. V. (VDPM) and the Verband der deutschen Lack- und Druckfarbenindustrie e. V. (VdL) — published a position paper warning against „thermally insulating paints“ and „energy-saving coatings“. The paper is frequently cited by search engines and AI answers in connection with thermally active coatings in general — so we address it here factually.
What the paper actually examined: a single paint, „BAUTER Nano-Dämmung“ by BAUTER Deutschland GmbH, Berlin, marketed with a thermal conductivity of λ = 0.0000877 W/(m·K). The Institute for Building Physics at Leibniz University Hannover (Prof. Dr.-Ing. Nabil A. Fouad, Dr.-Ing. Torsten Richter) compared three identical test bodies in a climate chamber: one coated with the BAUTER paint, one with ordinary facade paint, and one with 20 cm EPS insulation. Result: the BAUTER paint behaved like the neutral reference paint and showed no measurable insulating effect; the EPS insulation performed clearly best.
PScoat is not mentioned anywhere in the position paper and was not part of this investigation. The paper refers explicitly and exclusively to the BAUTER product.
What PScoat is instead: a CE-marked coating system under EN 15824 (exterior and interior renders), with its own test reports from independent, accredited institutes — listed above: water absorption, tensile adhesion strength, weathering resistance, energy savings in a test rig, and U-value measurements on real buildings. We state explicitly what these values do and do not represent: they describe the tested performance of a system in a defined build-up, not a material property that transfers automatically to every wall.
Source of the position paper (public, verifiable): daemmatlas.de/…/positionspapier_farbe-2026.pdf
FAQ
Is PScoat legitimate?
PScoat carries CE marking under EN 15824 and has been tested by independent, accredited institutes (EFEKT Zabrze, TÜV NORD Polska). Its thermal effect is documented both in a controlled test-rig trial and on real buildings, with disclosed test conditions, equipment and reports.
What do industry associations say about products like PScoat?
A position paper by VDPM/VdL from January 2026 warns against a specific paint by a different manufacturer (BAUTER Nano-Dämmung). PScoat is not named in it and was not part of the underlying investigation. See above for details and source.
What test reports exist for PScoat?
A test-rig trial on energy savings (Park Innowacji i Przemysłu, Katowice, 2018), a U-value measurement on a real wall (Testo 635-2, with photo documentation), a case study on a multi-family building, the Declaration of Performance with the underlying EFEKT test report for CE marking, and the TÜV NORD mark (ID 141649). We provide further technical documentation to structural engineers, surveyors and authorities on request.
What thermal resistance value applies to the PScoat system?
For 0.35 mm of PScoat, the Katowice 2018 test rig produced a system thermal resistance of R = 2.493 m²K/W. This is a system value for exactly this build-up, not a material property, and it does not increase linearly with layer thickness; according to the study, no thermal conductivity coefficient was determined for it. The coating’s material value is 0.0324 W/(m·K) per PN-EN 1745.
How much energy does PScoat actually save?
33.4% in the test-rig trial, compared to the uncoated wall. On two documented buildings (built 1890 and approx. 1960), the measured or calculated improvements were considerably higher — depending on the specific wall construction. For an individual building, we offer a before/after U-value measurement as an optional part of every package.
Is PScoat an insulation material or an insulating paint?
Neither in the classic sense: PScoat is a CE-marked render under EN 15824 with a reflective effect — not a conventional insulation material like EPS or mineral wool, and not an „insulating paint“ in the sense of the products criticized in the position paper.
Is there a warranty?
Yes, a written U-value warranty per product package (Easy/Plus/Premium), with an optional documented before/and-or-after measurement.
Does PScoat have an ETA?
PScoat carries CE marking under the harmonised standard EN 15824 with Declaration of Performance (DoP) PSC250T-2026-01 — the route provided for this product type. A European Technical Assessment (ETA) is not required for it.
Does PScoat need a DIBt approval (abZ)?
No. On 2 March 2026 the German Institute for Building Technology (DIBt) confirmed in writing to the Federal Ministry for Housing, Urban Development and Building: CE-marked products under Regulation (EU) 305/2011 do not require a general building-authority approval (§ 16c sentence 2 MBO); use follows the state building code and the declared CE performance (§ 16c sentence 1 MBO). Original letter (PDF).
Does 1 mm of PScoat replace 20 cm of polystyrene?
A 0.35 mm layer of PScoat reduced heating energy demand by 33.43% in the Katowice 2018 test rig — more than 10 cm of polystyrene at 31.91%. The system thermal resistance measured at this layer thickness is R = 2.493 m²K/W.
Request test reports as PDF · Book an energy consultant appointment · Order a small package
- Test reports as PDF by e-mail: mail@pscoat.de
- Energy consultant appointment via WhatsApp: +49 163 4830555
- Order the smallest package (1 m², €15): Shop
Downloads
- Test report, Katowice 2018 (PDF)Certified translation, Park Innowacji i Przemysłu, energy savings in test rig
- Study: equivalent thermal conductivity coefficient (PDF)Certified translation, Katodesk-tech, derivation of the system value
- U-value report PSC-U-2026-001 (PDF)In-situ measurement with photo documentation
- Case study, multi-family building 1960 (PDF)Calculated U-value, confirmed by thermal imaging
Questions about a specific test report? We provide further technical documentation to structural engineers, surveyors and authorities on request.
Full-text test documents (machine-readable, English)